SKEW=VALUE_0, NOREF=VALUE_0
Calibration Value Register
TENMS | Reload value to use for 10ms timing |
SKEW | Indicates whether the TENMS value is exact 0 (VALUE_0): 10ms calibration value is exact 1 (VALUE_1): 10ms calibration value is inexact, because of the clock frequency |
NOREF | Indicates whether the device provides a reference clock to the processor 0 (VALUE_0): The reference clock is provided 1 (VALUE_1): The reference clock is not provided |